Features
- 1 ½” wide material is manufactured from the same high quality material as MULTIVENT™.
- Material can be cut in a particular profile to match metal panel profile.
- Vented material will provide maximum air flow, yet prevent wind driven rain when compressed.
- Adhesive is applied as standard to allow for easy field installation.
Check Out Other CLOSURES AND VENTILATION Products
PIECES PER CTN. | FEET PER CTN. | ST CONTOURVENT DIMENSIONS | ||
---|---|---|---|---|
WIDTH | HEIGHT | |||
R-PANEL | 40 | 120 | 1 1/2" | 1 1/4" |
AG RIB | 60 | 180 | 1 1/2" | 3/4" |
PHYSICAL PROPERTIES | TEST METHODS | REQUIREMENT |
---|---|---|
Density (lb./cf) | ASTM D 3574 | 1.1 -- 1.6 |
110 mph Wind Driven Rain Test | not tested | |
Air Permeability (ft3/m./ft2 of Surface) | ASTM D737 | 700-800 |
Tear Resistance (lb./in. min.) | ASTM D 3574 | 2.9 minimum |
Tensile Strength (lbs/in2 min.) | ASTM D 3574 | 12 minimum |
Compress Force Deflection (lbs/in2 @ 25%) | ASTM D 3574 | .5 - .65 |
Elongation (% min.) | ASTM D 3574 | 90 minium |
Net Free Area | ||
Grandrib panel - 3/4” rib height (in2/lf of Ridge) | 1 side | 8.85 |
R panel - 1-1/4” rib height (in2/lf of Ridge) | 1 side | 14.76 |
Service Temperature Range | ||
High Intermittent (oF) | 250 | |
Continuous | 200 | |
Cold Temperature Resistance | -40 | |
Melt Temperature | 500 |