Features
- Lifetime 40 Year Warranty Long Life Fastener.
- 304 Stainless Steel cupped head & washer provide lifetime protection in the harshest environments. You may obtain a free copy of the written warranty upon request.
- 304 SS Woodbinder is an excellent choice for use in animal confinement applications or for aluminum liner panel applications.
- 304 SS Woodbinder is an economical alternative to Woodbinder ACQ.
- Type A point necessitates a pre-drilled hole in steel, but not aluminum.
FOR PROPER INSTALLATION, THE USE OF IMPACT DRIVERS ARE NOT RECOMMENDED FOR POWDER COATED OR ANY WET PAINTED FASTENER.
PULLOUT & PULLOVER VALUES ARE DETERMINED IN THE ST FASTENING SYSTEMS ENGINEERING LABORATORY USING STEEL PANELS/FRAMING & WOOD DENSITIES WHOSE STRUCTURAL PROPERTIES ARE FOUND IN PRESENT DAY PRODUCTS.
CHECK WITH ALUMINUM SUPPLIER FOR COMPATIBILITY WHEN USED IN COASTAL OR MARINE APPLICATIONS
SIZE | CARTON QTY. | WEIGHT/M |
---|---|---|
10 x 1” | 3000 | 9.0 |
10 x 1 1/2” | 2500 | 11.9 |
10 x 2” | 2000 | 14.0 |
SS | |
---|---|
HEAD STYLE | 1/4” CHWH |
POINT DIAMETER | 30º Sharp Point T-A |
MAJOR DIAMETER | .183/.189 |
MINOR DIAMETER | .126/.132 |
WASHER FACE DIAMETER | .500 |
HEAD ACROSS FLATS | NOM .250" |
ULT. TENSILE STRENGTH | 1135 LBS. |
MIN. TORSIONAL STRENGTH | 48 IN-LBS. |
NOM. SHEAR STRENGTH | 1034 LBS. |
SUBSTRATE | PENETRATION | VALUE |
---|---|---|
3/4” PLY | FULL | 616 |
5/8” PLY | FULL | 473 |
1/2” PLY | FULL | 312 |
7/16” OSB | FULL | 208 |
2 X Y. PINE* | 1” | 802 |
2 X Y. PINE* | 1 1/2" | 1176 |
2 X SPF* | 1 | 678 |
2 X SPF* | 1 1/2" | 913 |
* Y.PINE (Yellow Pine) * SPF (Spruce Pine Fir)
SUBSTRATE | GAUGE | THICKNESS | VALUE |
---|---|---|---|
304 SS Type A (EPDM) | 29 | .014 | 683 |
304 SS Type A (EPDM) | 26 | .018 | 870 |
Pull over values are calculated with a EPDM rubber washer assembled to cupped head screw with a .500” washer face.




The Type A point will tap a predrilled hole in steel but will self-drill through aluminum liner panels.

Notes:
- All strength values shown are ultimate values, expressed in LBS. Apply an appropriate safety factor to obtain design limits.