Eclipse MB™ WoodBinder®
Round head with 6–lobe recess driver provides an aesthetic, low-profile appearance on sidewall metal applications installed into wood girts.
Micro-Bit™ point quickly penetrates steel siding and eliminates metal shaving that can embed themselves in the rubber washer.
Undercut EPDM rubber washer provides a secure seal even when driven at an angle.
T-25-W driver specially designed to fit securely in the 6-lobe recess with no cam-out or paint damage.
SIZE | HEAD STYLE | CARTON QTY. | WEIGHT/M |
---|---|---|---|
10 x 1″ | TRUSS | 3000 | 8.0 |
10 x 1-1/2″ | TRUSS | 2500 | 10.1 |
10 x 2″ | TRUSS | 2000 | 12.2 |
10 x 2-1/2″ | TRUSS | 1500 | 15.4 |
10 x 3″ | TRUSS | 1000 | 17.2 |
DRILL POINT (DIA) | MAJOR DIAMETER | MINOR DIAMETER | WASHER/HEAD DIAMETER | HEAD ACROSS FLATS | ULT. TENSILE STRENGTH | MIN. TORSIONAL STRENGTH | NOM. SHEAR STRENGTH | |
---|---|---|---|---|---|---|---|---|
#10 | MICRO-BIT | .206/.200 | .126/.122 | .500 | N/A | 2023 LBS | 75 IN-LBS. | 1653 LBS |
SUBSTRATE | (1) – 1″ PENETRATION (2) – 1 1/2″ PENETRATION |
(3) – FULL PENETRATION (4) – 1/2″ PENETRATION |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MATERIAL | |||||||||||||||||
HRS PRIMED ONLY | 3/4″ PLY | 5/8″ PLY | 1/2″ PLY | 7/16″ OSB | 2X Y. PINE | 2X SPF | |||||||||||
NOM.GAUGE | 16 | 14 | 12 | ||||||||||||||
THICKNESS | .060 | .075 | .105 | (3) | (4) | (3) | (4) | (3) | (4) | (3) | (4) | (1) | (2) | (4) | (1) | (2) | (4) |
#10 | N/A | N/A | N/A | 536 | N/A | 420 | N/A | 379 | N/A | 190 | N/A | 929 | N/A | N/A | 640 | N/A | N/A |
DESIGNATION | MATERIALS | ||||||
---|---|---|---|---|---|---|---|
AZ55 GALVANIZED | G90 | ALUMINUM | SLOT EDGE PANEL | ||||
NOM. GAUGE | 29 | 26 | 24 | 22 | 20 | 21 | 29 |
THICKNESS | .014 | .018 | .024 | .030 | .036 | .028 | .014 |
#10 (EPOM WASHER ONLY) | 688 | 879 | N/A | N/A | N/A | 380 | N/A |
Metal to wood fastener designed with low-profile round head for sidewall metal applications installed into wood girts.
NOTES:
- 1-1 /2” LENGTH FULLY PENETRATES OSB AND PLYWOOD SHEETING
- 26 AND 29 GA. VALUES SHOWN WERE OBTAINED USING 80 KSI STEEL SHEETING. 24, 22, AND 20 GA. VALUES WERE OBTAINED USING 50 KSI MINIMUM STEEL SHEETING.
- BMT DENOTES BASE METAL THICKNESS AFTER REMOVAL OF PAINT FINISH AND METALLIC PROTECTIVE COATING.
- ALL STRENGTH VALUES SHOWN ARE ULTIMATE VALUES, EXPRESSED IN LBS. APPLY AN APPROPRIATE SAFETY FACTOR TO OBTAIN DESIGN LIMITS.
FOR PROPER INSTALLATION, THE USE OF IMPACT DRIVERS ARE NOT RECOMMENDED FOR POWDER COATED OR ANY WET PAINTED FASTENER.
PULLOUT & PULLOVER VALUES ARE DETERMINED IN THE ST FASTENING SYSTEMS ENGINEERING LABORATORY & BASED UPON WOOD DENSITIES FOUND IN PRESENT DAY WOOD PRODUCTS.
Drill point design consistently penetrates metal panels, which eliminates the need to “punch” the metal panels with a sharp point to start the drilling process.
MB point is excellent for penetrating multiple thicknesses of steel often found on ridge cap or trim applications.