TAPPING SteelBinder®
Tapping screws that are designed to be used in light gauge metal or light gauge metal in a pre-drilled hole.
Can be used as replacements for screws that have loosened from steel.
5/16” HWH with EPDM bonded sealing washer provides maximum pull over strength in high wind uplift applications.
EPDM rubber & HH with EPDM bonded sealing is vulcanized to a steel washer to form an excellent seal & will cover any existing hole to prevent leaks from reoccurring.
SIZE | POINT STYLE | HEAD STYLE | CARTON QTY. | WEIGHT/M |
---|---|---|---|---|
17 x 3/4″ | TYPE AB | 5/16″ HWH | 2000 | 14.0 |
17 x 1″ | TYPE AB | 5/16″ HWH | 2000 | 18.0 |
17 x 1-1/4″ | TYPE AB | 5/16″ HWH | 2000 | 22.0 |
17 x 1-1/2″ | TYPE AB | 5/16″ HWH | 1500 | 25.9 |
DRILL POINT (DIA) | MAJOR DIAMETER | MINOR DIAMETER | WASHER FACE DIAMETER | HEAD ACROSS FLATS | NOM. TENSILE STRENGTH | MIN. TORSIONAL STRENGTH | NOM. SHEAR STRENGTH | |
---|---|---|---|---|---|---|---|---|
17-14 | 45º Sharp Point | .280/.273 | NOM .220″ | N/A | NOM .375″ | 5160 LBS. | 220 MIN. | 3952 LBS. |
MATERIAL | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HRS PRIMED ONLY | AZ55 GALVALUME | G-90 GALVANIZED | HRS. PLATE | |||||||||||
NOM. GAUGE | 16 | 14 | 12 | 26 | 24 | 22 | 18 | 20 | 18 | 16 | 14 | 12 | 3/16″ | 1/4″ |
THICKNESS | .060 | .075 | .105 | .018 | .024 | .030 | .048 | .036 | .048 | .060 | .075 | .105 | .187 | .250 |
17-14 | 1409 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | 1119 | N/A | N/A | N/A | N/A | N/A |
MATERIAL | |||||||
---|---|---|---|---|---|---|---|
AZ55 GALVALUME | G90 | ALUMINUM | SLOT EDGE PANEL | ||||
NOM. GAUGE | 29 | 26 | 24 | 22 | 20 | 21 | 29 |
THICKNESS | .014 | .018 | .024 | .030 | .036 | .028 | .014 |
17-14 | 556 | 890 | 1197 | 1290 | N/A | N/A | N/A |
FOR PROPER INSTALLATION, THE USE OF IMPACT DRIVERS ARE NOT RECOMMENDED FOR POWDER COATED OR ANY WET PAINTED FASTENER.
PULLOUT & PULLOVER VALUES ARE DETERMINED IN THE ST FASTENING SYSTEMS ENGINEERING LABORATORY USING STEEL PANELS/FRAMING & WOOD DENSITIES WHOSE STRUCTURAL PROPERTIES ARE FOUND IN PRESENT DAY PRODUCTS.
ALL STRENGTH VALUES SHOWN ARE ULTIMATE VALUES, EXPRESSED IN LBS. APPLY AN APPROPRIATE SAFETY FACTOR TO OBTAIN DESIGN LIMITS.