Eclipse SteelBinder®
Truss Head with 6–lobe recess driver provides an aesthetic, low-profile appearance on sidewall metal applications installed into metal girts.
Self-drilling point penetrates steel thickness up to .210”
Undercut EPDM rubber washer provides a secure seal even when driven at an angle.
T-30W driver is designed to fit securely into the 6-lobe recess to prevent bit “camout.”
SIZE | HEAD STYLE | CARTON QTY. | WEIGHT/M |
---|---|---|---|
12-14″ x 3/4″ | TRUSS | 2500 | 10.7 |
12-14″ x 1-1/4″ | TRUSS | 2500 | 14.1 |
1/4″-14″ x 7/8″ STITCH | TRUSS | 2500 | 13.0 |
DRILL POINT (DIA) | MAJOR DIAMETER | MINOR DIAMETER | WASHER/HEAD DIAMETER | ULT. TENSILE STRENGTH | MIN. TORSIONAL STRENGTH | NOM. SHEAR STRENGTH | |
---|---|---|---|---|---|---|---|
#12 | .180/.175 | .215/.209 | .164/.157 | .544 T-30 6-Lobe Truss | 2900 LBS | 92 IN-LBS. | 1962 LBS |
#14 | .156/.150 | .246/.240 | .192/.185 | .533/.551 T-30 6-Lobe Truss | 3800 LBS | 150 IN-LBS. | 2850 LBS. |
MATERIAL | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HRS PRIMED ONLY | AZ55 GALVALUME | G-90 GALVALUME | HRS. PLATE | |||||||||||
NOM GAUGE | 16 | 14 | 12 | 26 | 24 | 22 | 18 | 20 | 18 | 16 | 14 | 12 | 3/16″ | 1/4″ |
THICKNESS | .060 | .075 | .105 | .018 | .024 | .030 | .048 | .036 | .048 | .060 | .075 | .105 | .187 | .250 |
#12 | 927 | 958 | 1678 | N/A | N/A | N/A | N/A | N/A | 729 | 787 | 1041 | 1372 | N/A | N/A |
#14 | N/A | N/A | N/A | 342 | 378 | 418 | 1038 | 620 | 1038 | N/A | N/A | N/A | N/A | N/A |
DESIGNATION | MATERIALS | ||||||
---|---|---|---|---|---|---|---|
AZ55 GALVANIZED | G90 | ALUMINUM | SLOT EDGE PANEL | ||||
NOM. GAUGE | 29 | 26 | 24 | 22 | 20 | 21 | 29 |
THICKNESS | .014 | .018 | .024 | .030 | .036 | .028 | .014 |
#12 | 687 | 1090 | 1299 | 1562 | N/A | N/A | N/A |
#14 | 746 | 960 | 1261 | 1376 | N/A | N/A | N/A |
NOTES:
- HRS (Hot Rolled Steel)
- Pull over values calculated with EPDM rubber washer assembled to cupped head screw with .544” washer face.
- All strength values shown are ultimate values, expressed in LBS. Apply an appropriate safety factor to obtain design limits
FOR PROPER INSTALLATION, THE USE OF IMPACT DRIVERS ARE NOT RECOMMENDED FOR POWDER COATED OR ANY WET PAINTED FASTENER.
PULLOUT & PULLOVER VALUES ARE DETERMINED IN THE ST FASTENING SYSTEMS ENGINEERING LABORATORY USING STEEL PANELS/FRAMING & WOOD DENSITIES WHOSE STRUCTURAL PROPERTIES ARE FOUND IN PRESENT DAY PRODUCTS.